- 1 year ago
Category
📚
LearningTranscript
00:00it is my great pleasure to be with you this time online I've been once to Algeria so this
00:15my second time but virtual hopefully third time will be physical again so without further ado
00:22because I'm in my clinic right now this is my disclosure the left anterior appendage closure
00:29as you already covered in your conference today the whole idea is about 90% of AF related strokes are
00:39coming from the appendage that's why this helped to close the left anterior appendage to prevent stroke
00:46and the patient can stop anticoagulation as you have covered I will go for the technical issues
00:51but quickly this demo will show the steps and then we will relate from the imaging point of view so of
00:58course transeptal puncture like anything done in the left side we have to puncture the symptom to
01:05cross to the left side and then the guide catheter and then the wire will be positioned in the left
01:10upper pulmonary vein and then the big tail which is the safe one to be put inside the little appendage
01:16and then the sheath will go over the big tail and then contrast will be injected to opacify the appendage
01:23in order to be measured and then the device which is here in my lecture I will be covering the watchman
01:28device will be unsheathed and then the device will be deployed here they are doing tuck test in and out to
01:34make sure it is really caught within the appendage and then if everything is is okay they will just deploy
01:42the device after 45 days we repeat the transit of jail echo again to make sure that there is no gaps in
01:48it in this realization happen and then the patient can safely stop anticoagulation so based on that
01:56what is my rule as a transit of jail echo person in this kind of procedure of course I have to assess the
02:03appendage but in terms of what I have to exclude anything by because we are going inside the appendage so
02:10any thrombi inside will be very risky number two I have to assess the shape of the appendage number
02:16three how many loops this appendage has and then the dimensions of the ostium and the lens of the
02:23appendage of course thrombi is quite common water dealing with patients of atrial fibrillation so
02:30that's why we are doing this but a thrombus in the day of the procedure is a contraindication because
02:36we are going really inside the appendage unlike other kinds of procedures like miter clip or other
02:41things maybe we can forgive a small thrombus inside the apex of the appendage but of course not a large
02:49one like this but lift it up in the closure no thrombus should be allowed within the appendage number two the
02:56shape of the appendage appendage is not one shape of course the common shape that we all think about is
03:03the wind soak type this wind soak type shape which is narrow neck and long limbs this one is the
03:10favorite shape for the left atrial appendage closure because it has a small ostium and long limbs if the
03:18ostium is small the device itself will be small and if the device small the legs of the device will be
03:24short so if I put a small device here and the legs are short they will not reach the top of the appendage or
03:31the apex of the appendage so the device would be very well seated at the ostium but look at the other
03:38extreme which is the broccoli tack very wide neck very wide and short lens of course a very wide neck
03:44very wide ostium means I need to have a very wide device a very big device if the device is big it is
03:51not big only in the head of the device the legs also the spider-like legs will be down very long because it
03:58is big if the device is big and the legs are too long if the appendage is shallow like in this case
04:06the ends of the legs will touch the floor of the appendage and then the device will bulge outside the
04:12appendage and we can and this will create something called the shoulder the shoulder is thrombogenic so
04:19we do not need a shoulder in the lift a little appendage closure the appendage has to be at the level of the of the S of the ostium
04:27what if the appendage has this chicken wing type shape so a first arm going down and then the second arm going somewhere else like
04:35chicken wing we don't care about the other wing if the length of the first arm and the ostium looks like the windsook one so we will deal with this one only
04:49if it is very wide and short we will deal with it as broccoli type if it is small and long we will deal with it as windsook type so it depends on the
04:58the first arm or first leg what about if the appendage has multiple loops the shape and all of these analysis is based on the
05:09major loop of the appendage so we're not going to find everyone the major loop the one at which we will
05:15the position the device is the one that we should assess the shape and dimensions and so on
05:22the number of loops this is what i was talking about before like maybe like 15 years ago i was under
05:28impression that most commonly we have one loop and that was not true actually because most commonly we
05:34have more than one loop about 50 percent of those sitting in the auditorium in front of me now 50 percent of
05:41you has two loops okay and only 20 percent of us or of those sitting in front of the
05:48screen now has uh only one loop so 20 of us that means when you screen a patient for a thrombus or for
05:56the appendage closure by te you should think that this patient is most probably is having more than one
06:03loop okay and order to exclude thrombi we need to screen all the loops to make sure that you covered everything
06:09because most probably this patient or this individual will have more than one loop what about the size of
06:16the appendage of course you have covered this but we we have tables if the ostium is between this number
06:22and this number and then the device size the suitable device size will be like this and if the ostium is
06:28like this the device will be like that and of course you can notice that we are usually oversizing the device a
06:33little bit because it has to be squeezed and compressed inside the ostium of the appendage
06:38so imaging where to size and what to use should we take if you are using 2d transistor gel echo two
06:47dimension only without 3d because the appendage is not a circle it is many times it's a bit over that
06:54means one dimension will not be enough if it is a circle one dimension in the middle will be enough but
06:59because it is many times oval a little bit or bizarre shaped like that so you need to get that in many
07:05degrees of course zero degrees like this if you pull the probe up you will have a view like this
07:11and then you freeze and measure in front of the ostium of the circ and then from the limbus here of the
07:18common ridge you go down about 1.5 centimeters to 2 centimeters and then you measure the ostium of the
07:23appendage and from the mid of this line you take another distance to the apex of the appendage
07:29this is called the usable length the length of the appendage and the ostium of the appendage
07:34this is one and then you do the same thing at 45 degrees again you measure the ostium and length
07:41the same thing at 90 degrees and then you measure the ostium and length and the same thing at 135 degrees
07:48135 is usually the longest length of the appendage and it simulates the one in fluoroscopy and you
07:54measure the ostium and length why is that again because there's not a circle in many situations
08:00if you have three dtee it is much more easier than this because one volume like this this volume is
08:06only for the appendage and the left hour will remain this is an on fast view for the appendage this is the
08:11whole appendage and you can see it's oval it is not a circle so mitral valve aortic valve so aortic valve
08:20might relate like long axis view and then this is the anterolateral commission a1p1 and then this is
08:26the appendage and this is the ridge commanding ridge and this is the left upper pulmonary veil
08:30from this view only one view only one acquisition is quite enough for me to get all the measurements i
08:36want because i will put it in the mpr multi-planary pre-construction in the 3d analysis station or the
08:44machine and then i can put my lines exactly at the ostium but the other lines in the middle
08:49of the appendage and then i can get an austral view of the appendage of course 2d transistor
08:55will not give you an austral view there is no access in 2d te that gives you an ostium of the
09:01appendage but by 3d te we can analyze that like ct and you can see it is quite dynamic okay you can see
09:10that's very dynamic so it is not only at any time of the cardiac cycle usually in systole is the widest
09:16uh dimension of the appendage and the same thing we measure the usable length of the appendage
09:21uh in all the views like that and this is very well correlated with the city measurements provided
09:27that you do this in in systole at in systole not in at any other phase of the cardiac cycle during the
09:35procedure itself of course we have to cross the system as we said after the transeptal puncture if you're using 2d
09:42the main the two main views for transeptal puncture you start usually by the bicavel view superior
09:48vena cava inferior vena cava that gives you the superior part of the septum inferior part of the
09:53septum and then the short axis base view that gives you the anterior part of the septum and the posterior
09:58part of the septum in the left atel abandoned closure we usually prefer to be in the inferior part of
10:04the septum and then usually the interventionist bolt bolts the catheter from the sbc going down down down
10:10till he reaches the suitable spot at the septum from the bicavel view at this moment i tell the
10:17interventionist wait for me and then i will go for the short axis base view to make sure he is not in
10:23the anterior part i have to be in the posterior part of the septum because the anterior part has the risk
10:29of puncturing the aortic root from inside the needle has a bit of curve like that it's not straight
10:35native transseptal puncture needle as you saw in the conference once it crosses it has a chance of
10:42going like this and hit the aortic root from inside but if you are in the posterior part of the septum
10:47you are safe this anatomical illustration is showing you the inter-atrial system from the right atrial
10:55aspect this is superior vena cava inferior vena cava right cuspid aorta and this is the pulmonary and so
11:00on so the septum is flat in front of you like the right anterior oblique view in the fluoroscopy
11:07the 2d te gives you the bicavel view which is almost at 90 degrees bicavel view and then the short axis
11:13base view but they are still 2d blades if you are using three-dimensional echo you can do much
11:20more easier and better a way of seeing the whole septum something called rattle 90 maneuver which is
11:27a maneuver that we have published about eight years ago or maybe 10 years ago rattle stands
11:34for rotate anti-clockwise tilt lift for 90 degrees rotate what rotate the 3d volume so i'm now speaking
11:41to the my echo uh colleagues this is only for echo guys by cable view you click the 3d zoom 3d zoom
11:49will give you two boxes you put the boxes at the septum cover the whole septum superior vena cava and
11:55inferior vena cava you make sure that you take the septum but take the septum only do not take
12:00the right atrial wall you need only the septum in both views take part of the aortic valve and
12:04posterior part of the septum now you are ready and then you click 3d zoom again you will get this view
12:09this 3d zoomed view is having the same orientation of the 2d view superior vena cava is here this is
12:15superior vena cava inferior vena cava inferior vena cava left atrium is here right atrium is here okay
12:21now rattle will start rattle at the end what i want from the rattle 90 maneuver by cable view the
12:27septum is flat but i need to see the septum flat in front of me like that uh in anatomically oriented
12:33view so superior vena cava inferior vena cava i need to see it like that so what to do by cable view you
12:39acquire by the 3d zoom you do rotate anti-clockwise tilt lift r a t l e this is rattle 90 maneuver you
12:47rotate anti-clockwise you will get the superior vena cava superior right atrium is down now right
12:53atrium is here and then tilt left you will face the septum and this is how we do it in real life
12:58superior vena cava super vena cava left atrium right atrium and then now we click 3d zoom get the
13:05boxes over the septum you will have this volume and then rotate anti-click wise and then by the attract
13:12ball tilt lift you will see the septum on fast view this brown color is the gain reduce the game down
13:18and then you will have a very nice view for the whole septum that patient had an asd by the way
13:23superior vena cava by some forward tilting and then some backward tilting you see the sbc station
13:30bad coronary sites so this is what the 2d will give you and this is what the 3d will give you very
13:37panoramic view for the whole septum and then you can use it for the transseptal puncture like this
13:42now the catheter is coming from the inferior vena cava towards the superior vena cava this is the
13:47coronary sinus this is the aortic valve ascending aorta and so on so you know anterior posterior superior
13:55inferior and this faint part is the fossa so you can guide the interventionist where to go and even
14:02you don't need to speak the interventionist can see the fossa here and this is the catheter and then
14:07now he is pulling down the catheter towards the fossa like that the needle i mean that's another
14:13example the needle was too anterior then he rotated rotate clockwise and then he fell inside the fossa as
14:20you can see and you can see this from the side by testing more or from the left atrium you can see the
14:26tinting more and more and so on good so now we crossed and this is the catheter inside the left
14:35atrium facing the commandant ridge left upper pulmonary vein here and this is the lift atrial
14:39appendage of course as any step in the lift atrium we need to throw a wire in the lift upper pulmonary vein
14:46and that can be guided by 2d or 3d te live 3d zoom mode for the mitral valve ridge lift atrial
14:53appendage is here left upper pulmonary vein so you can make it easier for the interventions to show
14:57him what is the appendage and where is the left upper pulmonary vein now after wiring pulmonary vein
15:05this is the big tail catheter you can see the big tail catheter with the uh curved tip now that's a
15:11panoramic view from above both atria this is the right atrium inter atrial septum catheter is coming
15:18from the right side puncturing the septum and going inside the appendage so now i'm inside the appendage
15:23intentionally by the big tail catheter this is the big tail catheter here and this is the sheath
15:30now injecting contrast as we said before in order to pacify the appendage and then introducing the
15:37sheath like that and this is how it looks in fluoroscopy we can see the tissues they see only the metals
15:45and then now unsheathing the device the device will pop up immediately like this after unsheathing
15:51once the interventions do this everybody actually will stop and look at the echo guy and ask the echo
15:59guy okay tell us uh should we release this device or there is any problem so what are the criteria
16:07done by echo to tell the interventionist you are okay or you are not okay something called pass
16:13criteria pass is stands for position anchor size c position is what as we said before the position we
16:22need the device to be at the ostia of the advantage not high so it will create a shoulder and not very
16:29low inside the appendage that means you left a small part of the appendage also you left a small
16:35appendage which is thrombogenic also you need to be at the ostia of the appendage number two the anchor
16:40means you need to make sure that the device is compressed inside the uh is not compressed it is
16:46caught well caught inside the appendage it is not loose and then you do the tech test as we'll see later
16:52and then the size means the device size uncompressed has for example 21 or 23 we need to make sure that
17:00it is smaller than this inside the appendage that means it is compressed and the last one is the seal that
17:05means you covered all the ostium of the appendage you do not have any gaps in between let's see that
17:11this is the position what i'm doing here i'm putting the appendage as much as i can inside the
17:18ostium of the appendage and i'm changing the angle you can see that i'm playing with the angle in and out
17:23in order to make sure that i am at the ostium in all the views this is the tug test the interventionist
17:31now is pulling on the device in and out to make sure it is really caught inside the appendage and
17:37you can see that in echo the size the compression you have to get a view to see the knob the middle
17:45knob of the device and then you have to to see the two shoulders that means you are right in the middle
17:49of the device and then you measure from here to here and then you compare that with the previous
17:55dimension of the device for example if the device was 24 uncompressed you have to see this dimension
18:02inside the body between 19 and 22 it has to be compressed between 8 percent to 20 percent so for
18:08example if it was 24 and then you measure inside the appendage and you find it 23 that means
18:14compression is not good that means the device is still smaller than the appendage you need a bigger one
18:19order to get more compression okay and then the seal you do the same thing change the angles to make
18:25sure you are covering all the ostium there is no gaps in between so if best criteria are met you tell
18:33the interventionist okay you can release this device and this is how it looks after the release this
18:38how it looks in 3d in day zero inside the procedure we repeat that after 45 days and then these features
18:47will be muffled will not be that clear like now because of the endothelialization and there is no
18:52gaps we may make sure that there is no gaps after 45 days if there is no gaps endothelialization happen
18:58the device is in place then the patient can safely stop the anticoagulation of course complications can
19:05happen like any interventional procedure thrombosis is very common in these patients you can see catheter
19:12and use thrombosis this patient have atrial fibrillation large lift atria they are already
19:18thrombogenic so there is a big chance of having this so make sure that you optimize the act during your
19:26procedure so as a conclusion t2d and 3d are crucial in in this kind of procedure it creates a common
19:33language between you and the interventionist and it can replace ct if the patient for any reason can't
19:39have a ct then maybe arena failure or so and thank you so much