• 1 year ago

Category

📚
Learning
Transcript
00:00So, we will discuss a very hot topic in TAVR about Bicuspid Aortic Valve.
00:15As all you know that Bicuspid Aortic Valve is a common congenital heart defect affecting up to 2% of the population.
00:24Bicuspid Aortic Valve accounts for up to 50% of patients requiring surgical aortic valve replacement and this is more evident in younger population.
00:35As TAVR becomes a therapeutic option for younger and healthier patients, Bicuspid Aortic Valve will be seen more often in the next future.
00:45So, why the Bicuspid Aortic Valve anatomy is always challenging?
00:49There is a lot of causes and a lot of factors make the Bicuspid Aortic Valve is challenging when you deal it with TAVR.
01:02Why asymmetrical calcium?
01:04Most commonly fused RAFI is asymmetrically calcified can cause valve to tilt or push lower during deployment.
01:12Of course, increase the risk of peripheral leakage, high calcium burden, calcium in Bicuspid Valve is a metablastic, snile calcification and this will increase the risk of stroke, pacemaker and root rupture.
01:29In Bicuspid Aortic Valve are more in Type 0 valves.
01:34And new studies have shown Type 1 valves are less elliptical than we thought.
01:39And always we noted that in Bicuspid Aortic Valve we have larger annulus than we expect and about 30% to 40% of the Bicuspid Aortic Valve has associated with Aortic aneurysm and aortopathy.
01:59And I will show you two cases and the why the Bicuspid Aortic Valve is more challenging.
02:07As you can notice it here, this is a female patient 67 years old and always we noted that Bicuspid Aortic Valve in younger population.
02:19She is morbid obesity, had a paroxysmal AF, she had attacks of syncope, she had severe aortic stenosis with mean gradient 55 mmHg.
02:31After her discussion, she referred for TAVR for her morbid obesity.
02:37And this is her echocardiography and you can appreciate here the mean gradient.
02:43And you can appreciate here, this is Type 0, Bicuspid Aortic Valve, as you can see this is her CT.
02:55And you can appreciate we have three types of Bicuspid Aortic Valve, tubular, flared and tapered.
03:06And you can measure, as Dr. Mohamed mentioned, you can measure the annulus in different ways.
03:15So you can perform traditional measurements at the annular level or at the LEVUTE.
03:23And you can appreciate the intercommercial distance which will measure it 4 mm above the annular plan.
03:33And all these diameters is very crucial and very important in Bicuspid Aortic Valve to avoid annular rupture.
03:40And you can appreciate here, this angle shows that we have a transverse aorta.
03:50The angle is very acute.
03:52So after crossing the valve and after periodilatation, we can't cross with the valve.
03:59This is a renewed R and we did a lot of maneuvers to cross the valve, but we failed.
04:06And you can appreciate here, every time the balloning do the same.
04:11And after proper periodilatation with bigger balloon, we thought that we can cross with the valve.
04:19As you can appreciate here, this is another periodilatation with bigger balloon.
04:26And every time the recoil is very high, as you can appreciate here.
04:32And we failed to cross the valve after all this periodilatation.
04:38So how to solve this?
04:40This is to change the wire.
04:42And we changed the wire for more stiffer wire.
04:47But we can't cross two.
04:49So we did like better wire, stiff wire in the LEV.
04:55And after we did, as you can appreciate here, there is two stiff wires in the LEV.
05:01And after that, we succeeded to cross the valve.
05:06And we deployed the valve.
05:10And you can appreciate here, the valve is very constrained.
05:13And this is typical picture of the self-examantable valve or any platforms in the bicuspid aortic valve.
05:23Another case, as you can appreciate here, this is 60 years old only.
05:29He has shortness of breath, orthopnea, baryxism, and nocturnal disease.
05:32He diagnosed as complete heartbreak three years before his presentation with severe ortex stenosis.
05:39He admitted in cardiac unit many times with decompensated heart failure.
05:43And he was diagnosed as severe ortex stenosis one year before the admission for TAVI.
05:47He has type 2 respiratory failure due to severe form of lung fibrosis.
05:52And this is why after heart team with his young, his age, they preferred to do for this patient TAVR, not surgical aortic replacement.
06:09And you can appreciate here, this is another type of aortic stenosis.
06:14And it's type 0 too.
06:16And it's not clear where is the leaflets, where is...
06:23And I expected that this patient, I will have more challenging in the crossing.
06:28But to cross this valve, it was a mess.
06:36As you can appreciate here, we tried AL1, AL2, Ray Jotkin, BigTail, Lima Caster, Tromo wire, normal straight wire, BTC wire, with rapid pacing, without rapid pacing.
06:48I did everything to cross this valve, but all were failed.
06:57So, we did injection to see where is the opening, and you can appreciate here, it's not clear.
07:05And after this injection, I tried, but we spent like 90 minutes to cross this valve.
07:11So, how to solve this, I thought that I can cross this valve anti-gradely via transvenous septal puncture, and you can appreciate here, this is inter-atrial septal puncture.
07:31And after I crossed from the left atrium to LV, the valve is crossed, you can appreciate here, the wire was crossed very easily.
07:47And after my wire in the aorta, I snared the wire, you can appreciate here, I snared the wire from the aorta to work again via transfemoral aorta.
08:01And this is very crucial, and this is very crucial, you have to be very cautious, not to cause any damage for the mitral valve apparatus.
08:17And now, my BigTail in the LV, after snaring, and my wire in the LV, and it's normal TAVI, this is pre-dilatation.
08:29As you can appreciate how the valve is very tight, and here, this is a typical form of the bicuspid aortic valve.
08:38This is another self-expandable valve, and post-dilatation, as you can appreciate here.
08:45And this is the final result, with excellent positioning of the valve, and his LV function is improved.
08:57So, bicuspid aortic valve anatomy has tackled in many different registries and in many trials, and always we have a procedure under expansion in all types of bicuspid aortic valve,
09:17and this is more evident from a lot of registries.
09:20And bicuspid should not be considered TAVI anymore for caster-based replacement.
09:27I mean, we have to deal with the bicuspid aortic valve when we need TAVI, with the proper platform, and with the proper preparation to tackle TAVI.
09:42And this is a lot of paper and a lot of publications discussing the difference between bicuspid and antericuspid aortic valve,
09:56and all favors to avoid TAVI in bicuspid aortic valve when it is combined with orthopathy or aortic aneurysm.
10:08And TAVI is a feasible option among a selected patient with bicuspid aortic valve anatomy,
10:14but the higher rates of moderate to severe barbapural leak, aneur rupture, and cerebral ischemic events observed in the bicuspid aortic valve.
10:21So, some recommend to put a protection device, cerebral protection device, before tackling the bicuspid aortic valve,
10:31and this is according to the protocol in some centers.
10:38So, my summary is, bicuspid aortic stenosis represents a heterogeneous anatomical cohort.
10:44Close attention should be paid to the valve morphology, calcium burden, and pattern.
10:48Data shows similar device success, mortality, and barbapural leak, perhaps higher rates of stroke, pacemaker, and root rupture.
10:57So, we have to deal cautiously with the bicuspid aortic valve.
11:02The current data suggests bicuspid anatomy is amenable to TAVR with current generation TAVR technology with acceptable clinical outcomes.