00:09In the drawing we now have the networks drawn in profile views.
00:14We're going to make some changes to the network in both plan and profile.
00:18In the upper viewport we're looking at the junction of McAulister Boulevard and Sycamore Heights.
00:24In the bottom viewport zoom to structure MH5 as shown.
00:30In the top viewport select the structure. The editing grips are displayed.
00:37The square grip allows you to move the structure and the circle grip will rotate the structure.
00:46Use the square grip to move the structure to a new location.
00:50When you move a structure the connected pipes stay connected and move with the structure.
00:57In the profile view notice that the rim elevation of the structure remains connected to the reference surface.
01:05Move the structure back to the intersection of the alignments as shown.
01:10Now select the pipe to the right of the structure.
01:13The square grip in the middle of the pipe will enable you to move the entire pipe to a new
01:20location.
01:21The direction of the pipe remains fixed.
01:27Turn on dynamic input on the status bar.
01:31If it's not visible use the customization button as shown to make it visible.
01:38With dynamic input turned on, the arrow grip in the middle of the pipe allows you to change the pipe
01:45diameter or width.
01:47Dynamic input allows you to view a readout of the selected pipe size in feet.
01:53You could also type a value into the input field.
01:57Zoom to the left hand end of the pipe and select it again.
02:02The arrow grip at the end of the pipe allows you to shorten or lengthen the pipe.
02:09You can see in the structure properties here that the connections show three pipes are still connected.
02:15You can use this feature to change the position of the end of the pipe within the manhole structure.
02:23The square grip at the start or end of the pipe allows you to move the point to a new
02:27location,
02:29disconnecting it from the structure and changing the pipe direction.
02:34You can reconnect a pipe to a structure by using the square grip and dragging the end point back over
02:41the structure
02:42until the connection symbol is displayed.
02:45Now pan across in the top viewport to the pond.
02:50In the bottom viewport pan the profile view to show the structure at the pond.
02:57This structure is currently a manhole but should be a headwall.
03:02Select the structure in plan.
03:05Right click and choose swap part.
03:09In the swap part size dialog select one of the concrete rectangular winged headwall parts and click OK.
03:18You can see that the part has changed in the profile view although in plan it still shows as a
03:24circle.
03:27Select the structure in plan.
03:29Right click and open the structure properties.
03:33On the information tab set the style to headwall.
03:37This shows the headwall in its true shape.
03:40You can now select the headwall and rotate it so that it is parallel with the embankment.
03:47In the profile view we need to adjust the position of the pipe relative to the pond.
03:54Select the pipe and using the central square grip move it up in the view.
04:00You can use the diamond grips on the end of the pipe to adjust the crown, center or invert elevation
04:06of the pipe.
04:08By selecting two adjacent pipes you can use the diamond grips to grip edit the ends of the two pipes
04:15to the same elevation as shown.
04:20The headwall is currently placed inside the embankment of the pond.
04:25We can adjust its position in plan so that it sits on the edge of the pond in the profile
04:31view.
04:33In the profile you can use the arrow grip on the top of a structure to edit its top or
04:39rim elevation.
04:41Now using the object viewer review the position of the headwall relative to the pond.
04:48We have part of our pipe network shown in plan and in profile.
04:52We are going to edit the network using the pipe and structure properties and some other methods.
04:59Select pipe P7 in the plan.
05:02Right click on it and choose pipe properties.
05:06You can also use pipe properties from the pipe network contextual ribbon tab.
05:12In the pipe properties on the information tab you can edit the pipe name and description
05:18and change the pipe style and render material.
05:21Go to the part properties tab.
05:24The pipe flow direction method sets the rule that is used to determine the direction of flow in the pipe.
05:31The reference surface changes the surface used to determine the cover depth of the pipe.
05:38In the geometry section you can change the slope of the pipe holding either the start or the end of
05:44the pipe fixed.
05:46Change the value of pipe slope hold start to minus 1% and click apply.
05:54Note the updated pipe in the profile view.
05:57Change it back to minus 0.49% and click apply.
06:02You can edit the pipe elevations of either end of the pipe by invert, crown or centre line of the
06:08pipe.
06:09You can also edit the coordinates of either end of the pipe.
06:13Change the end invert elevation to 647 feet and click apply.
06:18Then change it again to 648 feet and click apply.
06:23The resize behavior controls which elevation remains fixed if the pipe size is changed.
06:31Set the resize behavior to crown.
06:34Now if the pipe size is changed the crown elevation will be used for the elevation of the pipe.
06:39The hydraulic properties are only used when the pipes are analyzed and can be used to store information about the
06:47results.
06:49Under part data the Manning coefficient can record the roughness coefficient of the pipe material for flow analysis.
06:58The Hayes and Williams and Darcy Weisbach factors are alternatives.
07:03At the bottom is the inner pipe diameter which can be used to change the diameter of the pipe.
07:09Change the inner pipe diameter to 24 inches and click apply.
07:17You can see in the profile view the crown has been held fixed.
07:21Change the inner pipe diameter back to 12 inches.
07:27On the rules tab you can review the pipe rules that were applied to the pipe together with their actual
07:33values.
07:35And you can check the status of the rules.
07:38Here you can see both the minimum slope and minimum cover depth rules were violated.
07:44If I were to change the slope of the pipe in the part properties so that it meets the slope
07:49rules,
07:50you can see that back in the rules tab the minimum slope warning has been removed.
07:56Click OK to dismiss the dialog.
07:59Now select the structure MH7.
08:03Right click and choose structure properties.
08:07On the information tab we have the same options for changing the name and styles for the structure.
08:14On the part properties tab we can change the reference surface that is used to calculate the rim elevation of
08:20the structure.
08:21You can see the structure update in the profile view if you swap the reference surface.
08:28Under geometry you can change the rotation and insertion coordinates of the structure.
08:33The insertion rim behavior controls how the rim elevation is calculated.
08:40Automatic surface adjustment controls whether the rim elevation is calculated automatically from the surface or is set manually.
08:49The surface adjustment value allows you to set an offset from the calculated surface elevation,
08:56for example to have the structure protrude above the ground.
09:00The sump behavior controls whether a structure has a sump below the pipes,
09:05for example when the structure is a catch pit.
09:10You can set the sump method and depth here.
09:14Again the hydraulic properties are used to provide inputs or store results from drainage analysis applications.
09:22Under part data you can change the structure type and benching method which are used for analysis.
09:29You can change the rim to sump height of the structure and set other values such as wall and floor
09:36thickness and the structure material.
09:40Other dimensions such as frame length and width may not be populated and the available options will vary depending on
09:48the catalogue and the parts that are used.
09:50The inner structure diameter can be used to change the diameter of the manhole.
09:56Change the inner structure diameter to 96 and click apply.
10:01Note the changes in the profile view.
10:04Set it back to 60.
10:07On the connections tab you can review the pipe connections to the structure.
10:12The status column displays the rule status for connected pipes.
10:17In here you can change the elevations and slopes of the pipes.
10:22When selecting multiple pipes you can right click and then match the pipe elevations across the selected pipes.
10:32The rules tab displays the structure rules that are assigned to the structure together with the actual values.
10:39The status column will display any rules that are violated.
10:45Click OK to dismiss the properties.
10:49Now select the Storm1 network in Prospector.
10:52Right click and choose edit network.
10:56This will call up the network layout tools enabling you to add to the network.
11:02On the right hand side of the tools you'll find the pipe network vistas button.
11:06This will open tables for pipes and structures in the panorama viewer which you can use for editing.
11:12Click on the button to open the vistas and then go to the pipes tab.
11:17Here you can see pipe information in tabular form.
11:21Items not greyed out can generally be edited.
11:24The status column displays a summary of rules that are violated.
11:29Note that the inner pipe diameter cannot be edited from here.
11:33You can change the surface and edit the pipe coordinates, elevations or slopes.
11:42Review the properties that are available.
11:45Go to the structures tab.
11:47Again you will see a table of the structure properties.
11:51Where you can edit names, styles, the reference surface and structure coordinates and elevations.
12:02You cannot change the structure diameters here though.
12:06Close the panorama viewer and the network layout tools.
12:11Switch the drawing back to a single viewport.
12:15We need to combine the storm 2 network that runs along woodside view with the storm 1 network for analysis
12:24purposes.
12:25From Prospector click on the storm 2 network, right click and choose select.
12:31From the pipe network contextual ribbon tab on the modify panel choose merge networks.
12:38In the merge dialog select storm 2 as the network to be merged and click OK.
12:46In the destination dialog select storm 1 as the destination network and click OK.
12:53In Prospector you can see there is now only one network, storm 1, and the two networks have been merged.
13:01Now zoom to manhole 2 at the junction of Woodside View and McAllister Boulevard.
13:07At this location there are in fact still two structures.
13:11Manhole 2 is from storm 1 and there is an end structure from the storm 2 network.
13:18In Prospector use the item list view for the structures and sort the list by clicking on the name column
13:26header.
13:27Select structure 15 from the list which was the last structure in the storm 2 network.
13:35Move the cursor into the model space and use the delete key to delete the selected structure.
13:42Then select the last pipe on that run and using the end square grip drag the pipe away from the
13:48structure and then drag it back until the connection symbol is shown.
13:53Then click to reconnect the pipe to the structure.
13:56We now need to rename the pipes and structures that were merged from storm 2 to continue the naming convention
14:03and numbering used in storm 1.
14:06Looking at the pipes in the item list view, the pipes from the storm 2 network have been added but
14:12the names do not match those from storm 1.
14:14From the modify ribbon tab on the design panel click on pipe network then from the modify panel drop down
14:23choose rename parts.
14:27On the command line it is asking for the first part to be renamed.
14:31In the model pan to the first structure on the run and select it and then pan to the last
14:37pipe on the run and select that.
14:40Press enter.
14:42In the rename parts dialog 4 structures and 4 pipes have been selected.
14:47For structures click on the name template button and change the name format for the structures to MH and then
14:54a space and then add the field next counter.
14:58Set the starting number to 12 and click OK.
15:04For pipes set the name template to P with a space and then next counter without the brackets.
15:14Set the starting number to 11.
15:18Select rename existing parts then click OK to rename the structures and pipes.
15:24In Prospector reviewed the pipe and structure, names.
15:30In Prospector, review the pipe and structure names.